SHYCOCAN VIRUS ATTENUATION DEVICE

Virology Performance Tests

SL.NOLaboratoryTest OrganismTest BriefTest Result
1Laboratorios de Especialidades Inmunologicas (LEI), MexicoEquine ArteritisGlass plate with virus exposed for 15 and 120 min99.9%
2Aquadiagnostics/IAPMO, BangaloreMS2 phageAcrylic sheets with virus placed at 12ft distance from the EUT; Tested for exposure time 30 min, 1 hr, 2 hrs99.99%
3Indian Institute of Technology (IIT), GuwahatiAvian CoronavirusAerosol test conducted with sampling time 15, 60 and 120 min100%
4Netherlands Organisation for Applied Scientific Research – (TNO), NetherlandSARS-CoV-2Stainless steel with virus exposed for 15 min94.9%
5Center for Cellular And Molecular Biology (CCMB), HyderabadSARS-CoV-2Acrylic plate with virus exposed for 10, 30 and 60 min96.00%
6Kasetsart University, ThailandFeline coronavirusVirus exposed for 5, 15 and 30 min100%

Safety Test (Electrical and Environment)

SL.NOLaboratoryType of TestTest ObservationInterpretation
1TUV, MalaysiaIEC 60335-1-2010Safety of house hold and similar electrical appliancesElectrically safe to use
2TUV, MalaysiaIEC 62233 – 2005Measurement methods for electromagnetic fields of household appliances and similar apparatus with regard to human exposureSafe to use
3Underwriters Laboratories, IndiaIEC 60335-1-2010Safety of house hold and similar electrical appliancesElectrically safe to use
4Underwriters Laboratories, IndiaIEC 61236-1-2012EMC Requirements Conducted Disturbances Radiated DisturbancesEMC requirements Electrically safe to use
5SGS , UAEDeclaration of conformity declaration of accountability, as per UAE RoHS Decision number.10 of 2017Restriction of the use of certain hazardous substances in electrical and electronic equipmentRoHS environmental safety
6EVS Associates AustraliaOzone Emission testOzone Generation Monitoring test for 8hrs to ascertain the safetyEnvironmental Safety
7Shreis Scalene Therapeutics LLC, USAOzone Emission testOzone monitoring test for 8hrs to ascertain the safetyEnvironmental Safety
8FX Masse, USAIonizing Radiaiton Emission TestTest to detect ionizing radiation along the external surface of its emission grill, sidewall, and rear, with the power turned on and offNo harmful radiaiotns detected
9SN Solutions, IndiaIonizing Radiaiton Emission TestTest to detect emission of harmful radiationsNo ionising radiation (UV, X-Ray, Alpha, Beta, Gamma) was found

Safety Test (Humans and Animal)

SL.NOLaboratoryType of TestTest ObservationInterpretation
1Indian Institute of technology Guwahati (Assam)Cell viability and cell toxicity study done with human alveolar basal epithelial cellsCell viability found similar to controlled cellsSafe to use for human beings (Human Cell Safety)
2Madras University, ChennaiCell viability and cell toxicity study done with Vero Cells (African Green Monkey kidney epithelial cell)No significant difference between viability of control and exposed cellsSafe to use for pet animals (Animal cell safety)

Bacteria, Fungii & Mold test

SL.NO Laboratory Type of Test Test Observation Interpretation
1 Lonestar Technical Services, Dubai Inspect change in air and surface microbial parameters in a hospital Exposed sample had lesser TBC, Yeast and Mold as compared to the control sample The monitored area obsreved a drop in TBC, Yeast and Mold count (in not natural environment) post exposure
2 Scalene Energy Research Institute, India Bacteria behaviour to exposure to SHYCOCAN in natural environment Device had no effect on the bacterial activity in natural environment Device has no impact on bacteria residing in natural environment
3 Scalene Energy Research Institute, India Fungus behaviour to exposure to SHYCOCAN in natural environment Device had no effect on the fungus in natural environment Device has no impact on bacteria residing in natural environment
4 Dubai Municipality, Dubai Antimicrobial Effectiveness of the equipment inside a room Reduction in % of microbial activity (TBC, Yeast & Mold) Significant microbial reduction obsreved after 24hrs of device exposure